It’s been a week of travel, so we’ll close it with a video from Emerson’s Rosemount measurement team on how to install an Annubar averaging pitot tube flowmeter. The Youtube video shows the installation process for a Rosemount 485 Pak-Lok flowmeter.

This device, used for liquid, gas, and steam measurement applications, is an integrated DP flowmeter with an Annubar primary element packaged with a Rosemount pressure transmitter.

From Wikipedia:

An annubar is similar to a pitot tube used to measure the flow of gas or liquid in a pipe.

The pitot tube measures the difference between the static pressure and the flowing pressure of the media in the pipe. The volumetric flow is calculated from that difference using Bernoulli’s principle and taking into account the pipe inside diameter.[1]

With that as background, here’s the 3-minute Rosemount Annubar Pak-Lok Flowmeter Installation video:

Popular Posts

Comments

Follow Us

We invite you to follow us on Facebook, LinkedIn, Twitter and YouTube to stay up to date on the latest news, events and innovations that will help you face and solve your toughest challenges.

Do you want to reuse or translate content?

Just post a link to the entry and send us a quick note so we can share your work. Thank you very much.

Our Global Community

Emerson Exchange 365

The opinions expressed here are the personal opinions of the authors. Content published here is not read or approved by Emerson before it is posted and does not necessarily represent the views and opinions of Emerson.

PHP Code Snippets Powered By : XYZScripts.com